Model
|
Volume Flow (m3/min)
|
Discharge Pressure(Mpa)
|
Power(Kw)
|
Noise[dB(A)]
|
Outlet Dimension
|
Weight(Kg)
|
External Dimension(L×W×H mm)
|
|
RS45H-7
|
8.13
|
0.7
|
45
|
71
|
DN50
|
1100
|
2004×1237×1636
|
|
RS45H-8
|
7.7
|
0.8
|
|
RS45H-10
|
7.15
|
1
|
|
RS45H-13
|
6
|
1.3
|
|
RS55-7
|
10.53
|
0.7
|
55
|
74
|
DN50
|
1180
|
2004×1237×1636
|
|
RS55-8
|
9.92
|
0.8
|
|
RS55-10
|
8.7
|
1
|
|
RS55-13
|
7.5
|
1.3
|
|
RS65-7
|
12.2
|
0.7
|
65
|
75
|
DN50
|
1250
|
2004×1237×1636
|
|
RS65-8
|
11.6
|
0.8
|
|
RS65-10
|
10.1
|
1
|
|
RS65-13
|
8.5
|
1.3
|
|
RS75-7
|
13.6
|
0.7
|
75
|
76
|
DN50
|
1350
|
2004×1237×1636
|
|
RS75-8
|
12.6
|
0.8
|
|
RS75-10
|
11.6
|
1
|
|
RS75-13
|
9.8
|
1.3
|
|
Remark: Power supply: 380V/3/50Hz Starting way: star-delta pressure drop. Volume flow is the tested volume flow under the condition of 20℃ ambient temperature and rated working pressure in accordance with the requirements of Gb3853(eqvISO1217). Oil content of discharged gas: ≤3ppm Temperature of discharged gas: AMT +5~8℃. (water-cooling style: ≤40℃). Noise of air-cooling style+2dB(A). The letter “W”is added behind the power value of Model No. to indicate Water-cooling style, i.e.: RS75W-8
|
Decruitment for regional agents capable of after-service